Transmission Lines
|
|
Our work on transmission and distribution lines typically include the design and detailing of all or some of the following: plan and profile of transmission line route, bills of materials, caisson foundations and structures, lattice steel structures, steel poles, technical specifications for construction, etc. |
|
Pole structures near Trans-Canada Pipelines Limited, Station 134, Bowmanville, Ontario. |
|
Transmission Lines |
|
Steel pole carrying distribution lines across a river in Oakville, Ontario |
|
Power lines near Greenfield Energy Centre, Ontario |



|
Engineering Solutions |
|
Chimax Inc. |
|
to power your lives to empower your community |
|
Chimax Inc. |
|
To contact us: General Inquiries 3950 Fourteenth Avenue Suite 506 L3R 0A9 Canada Tel : (905) 305-6133 Fax : (905) 305-6132 E-mail : chimax@chimax.ca |
|
Transmission and Distribution Line Design · Kruger, Port Alma Wind Farm – 34.5 kV collector line (21 km), 34.5/230 kV transformer station, Merlin, Ontario · Enbridge Ontario Wind Power – 44 kV collector line (51 km) and 230 kV switchyard, Kincardine, Ontario · Yukon Energy Corportion – 138kV transmission line, Carmack to Stewart Crossing (180km), 25 kV distribution line Minto Landing to Minto Mine (28 km), Yukon · Suncor, Ripley Wind Farm – 34.5 & 69 kV Collector Lines, Ripley, Ontario Design of pole line. · Sithe Energies Canadian Development Ltd. — Goreway Switching Station and 230kV double circuit (2.3 km) transmission line, Brampton, Ontario · Erie Shore Wind Farm – 34.5 kV Collector Lines (28 km) and 34.5 kV/115 kV transformer station, Port Burwell, Ontario · Prince I and Price II Wind Power – 30 kV substation foundation and detail design, Prince II 34.5 kV collector line (18 km), Ontario · Epcor, Kingsbridge I Wind Farm – 27.6 kV Collector / Transmission Lines (40 km) Goderich, Ontario, Pole Line design · Transalta Energy Corporation, Transalta Sarnia - 230kV Double Circuit Transmission line, Sarnia, Ontario – Design of transmission line, equipment bill of material, caisson foundation and structures, provided technical specifications for construction. · ATCO Electric Limited - 240kV Double Circuit Transmission Line Structures, Alberta Design & detail of all lattices steel structures for the double circuit transmission line. · Newfoundland and Labrador Hydro, TL 218/ TL 236 Upgrade Study Report, Newfoundland Study of upgrade and replacement for the existing 230kV double circuit line (approx. 10km long) with steel pole / lattice steel tower/ or modification to existing structures. · Barbados Light & Power Company Ltd, 69KV Transmission Line Project, design of the transmission line, steel pole structures & foundations · CEATI , Wind and Ice Storm Mitigation Interest Group (WISMIG) – Involved in the CEA study report including Post-Storm Inspection & Assessment On The Lattice Steel Tower of the Existing High Voltage Transmission Line. |
|
Chimax Inc. © MMVIII |